描述
Features
- Flows to 120 L/min (32 US gpm)
- Pressures to 70 bar (1015 psi)
- Port size 1 in.
- Out-to-in filter element flow path
规格
Filter Housing
- Maximum Allowable Working Pressure:
70 bar (1015 psi) - Rated Fatigue Pressure:
0 - 40 bar (580 psi) per NFPA T2.6.1 R2-2001 CAT C/90, verified by testing at 0 - 46.5 bar (675 psi) - Fluid Compatibility:
Compatible with all petroleum oils, water glycols, water-oil emulsions and most synthetic hydraulic and lubrication fluids - Temperature Range:
Maximum operating temperature: 120 ˚C (250 ˚F)
Minimum operating temperature: -25 ˚C (-13 ˚F)
Minimum ambient temperature: -40 ˚C (-40 ˚F) - Bypass Valve Settings:
‘B’ option – 3.4±0.3 bard (50±4 psid)
‘G’ option – 4.5±0.5 bard (65±7 psid) - Indicator Pressure Settings:
2.4±0.3 bard (35±4 psid) for ‘B’option
3.4±0.5 bard (50±7 psid) for ‘G’option - Materials of Construction:
Head - SG Iron
Bowl - Aluminium
Filter Element
- Filter Element Collapse Pressure:
10 bard (145 psid) - Filter Element Construction:
Inorganic fibers impregnated and bonded with specifically formulated resins. Polyamide endcaps. Corrosion protected carbon steel core.
Dimensional Drawings
性能
Pressure Drop Information
Housing pressure drop using fluid with 0.9 S.G.
Housing pressure drop is directly proportional to specific gravity.HCG300 Filter Elements – bard/1000 L/min (psid/US gpm)
Length Code | CN | CS | KD | CT |
04 | 5.60 (0.34) | 4.17 (0.23) | 2.68 (0.15) | 2.87 (0.16) |
08 | 3.04 (0.17) | 2.26 (0.12) | 1.41 (0.08) | 1.56 (0.09) |
Multiply actual flow rate times factor in
Sample ΔP calculation
F310 Series 4” length housing with C16 ports using KN grade media. Operating conditions 100 L/min flow rate using a hydraulic fluid at 20
Total FilterΔP
= ΔP housing + ΔP element
= (0.32 x 1.2/0.9) bard (housing)
+ ((100 x 5.35/1000) x 20/32 x 1.2/0.9) bard (element)
= 0.427 bard (housing) + 0.445 bard (element)
= 0.873 bard (12.7 psid)
类型
Housings, Vessels, or Assemblies
应用
Heavy Hydraulic, Heavy Lubrication, Medium & Light Fuel, Medium & Light Hydraulic, Medium & Light Lubrication
订购信息
Part Number | Description |
HZF310A16CNSS00001 | HZF310A16CNSGD1X160 |
HZF310C16CSRB00001 | HZF310C16CSRB11X160 |
HZF310C16CSSS00001 | HZF310C16CSSGD1X160 |
HZF310A16CSRB00001 | HZF310A16CSRB11X160 |
* Other options available, contact factory
Element P/N: HCG300F [Table 2] [Table 3]Z
Seal P/N: G300SKZ
Table 1: Housing Port Style Options
Code | Port Style |
A16 | SAE J1926 straight thread |
C16 | BSP threads to ISO228 |
Table 2: Filter Element Options
Code | ßx(c) ≥1000 based on ISO 16889 |
CN | 7 |
CS | 12 |
KD | 19 |
CT | 22 |
Table 3: Length Options
Housing Code | Element Code | Length (in)* |
R | 4 | 127 mm (5.00 in.) |
S | 8 | 219 mm (8.62 in.) |
* Nominal length
Table 4: Valve Options
Code | Option |
B | 3.4 ± 0.4 bard (50 ± 6 psid) |
G | 4.5 ± 0.5 |
Table 5: Differential Pressure Indicator Port Options
Code | Indicator |
D | Visual indicator |
1 | Machined port with plastic shipping plug Indicator must be installed prior to operation |
检查