G410 Series Versalon® High Pressure Filters product photo Primary L

G410 Series Versalon® High Pressure Filters

Features

  • Flows to 250 L/min (66 US gpm)
  • Pressures to 420 bar (6090 psi)
  • Port size 1 in. and 114 in.
  • Out-to-in filter element flow path


Contact Us
* 必填项

描述

Features

  • Flows to 250 L/min (66 US gpm)
  • Pressures to 420 bar (6090 psi)
  • Port size 1 in. and 114 in.
  • Out-to-in filter element flow path

规格

Filter Housing

  • Maximum Allowable Working Pressure:
    420 bar (6090 psi)
  • Rated Fatigue Pressure:
    0-240 bar (0-3480 psi) per NFPA T2.6.1 R2-2001
    CAT C/90. Verified by testing at 0-280 bar (0-4060 psi) for 1 million cycles. Contact Pall for applications with higher pressures at lower cycles
  • Fluid Compatibility:
    Compatible with all petroleum oils, water glycols, water-oil emulsions and most synthetic hydraulic and lubrication fluids
  • Temperature Range:
    Maximum operating temperature: 120 ˚C (250 ˚F)
    Minimum operating temperature: -25 ˚C (-13 ˚F)
    Minimum ambient temperature: -40 ˚C (-40 ˚F)
  • Bypass Valve Settings:
    ‘G’ option 4.5 ± 0.5 bard (65 ± 7 psid)
  • Indicator Pressure Settings:
    3.4 ± 0.4 bard (50 ± 6 psid)
  • Materials of Construction:
    Head: SG Iron
    Bowl: Carbon steel

Filter Element

  • Filter Element Burst Pressure:
    10 bard (145 psid)
  • Filter Element Construction:
    Inorganic fibers impregnated and bonded with epoxy resins. Polyamide endcaps. Corrosion protected carbon steel core.

Dimensional Drawings

性能

Pressure Drop Information

Housing pressure drop using fluid with 0.9 S.G.

Housing pressure drop is directly proportional to specific gravity.



HCG300 Filter Elements – bard/1000 L/min (psid/US gpm)

Length Code CN CS KD CT
4 5.60 (0.34) 4.17 (0.23) 2.68 (0.15) 2.87 (0.16)
8 3.04 (0.17) 2.26 (0.12) 1.41 (0.08) 1.56 (0.09)
10 2.42 (0.13) 1.80 (0.10) 1.13 (0.06) 1.24 (0.07)


Multiply actual flow rate times factor in table above to determine pressure drop with fluid at 32 cSt (150 SUS), 0.9 S.G. Correct for other fluids by multiplying new viscosity in cSt/32 (SUS/150) x new S.G./0.9. Note: factors are per 1000 L/min and per 1 US gpm.

Sample ΔP calculation

G410 Series 8 in. length housing with C20 ports using KN grade media. Operating conditions 100 L/min flow rate using a hydraulic fluid at 45 cSt and specific gravity (s.g.) 1.2.

Total Filter ΔP
= ΔP housing + ΔP element
= (0.22 x 1.2/0.9) bard (housing)
+ ((100 X 2.75/1000) X 45/32 X 1.2/0.9) bard (element)
= 0.29 bard (housing) + 0.51 bard (element)
= 0.81 bard (11.8 psid)

类型

Housings, Vessels, or Assemblies

应用

Heavy Hydraulic, Heavy Lubrication, Medium & Light Fuel, Medium & Light Hydraulic, Medium & Light Lubrication

订购信息

Assembly P/N*:
  • HZG410A16CSSG1X160
  • HZG410A20CSKG1X160
  • HZG410C16CNRG1X160
  • HZG410C16CNSGBX160
  • HZG410C16CSRG1X160
  • HZG410C20CNSGBX160
  • HZG410C20CSKGDX160

* Other options available, contact factory


Element P/N: HCG300F [Table 3] [Table 4] Z

Seal P/N: G400SKZ

Table 1: Housing Port Style Options

Code Port Size Port Style
A16 1 in. SAE J1926 straight thread
A20 1 14 in.
C16 1 in. BSP threads to ISO228
C20 1 14 in.

Table 2: Filter Element Options

Code ßx(c) ≥1000 based on ISO 16889
CN 7
CS 12
KD 19
CT 22

Table 3: Length Options

Code Element Length Code Length (in)*
R 4 130.4 / 131.0 mm (5.13 / 5.16 in)
S 8 222.6 / 223.2 mm (8.76 / 8.79 in)
K 10 274.3 / 274.9 mm (10.8 / 10.82 in)
* Normal Length

Table 4: Differential Pressure Indicator Options

Code Indicator
B Machined port with blanking plug
1 Machined port with plastic shipping plug
Indicator must be installed prior to operation
D Visual Indicator

检查