For "Sterile" Filtration of Beer
Pasteurizer replacement filter cartridges are hydrophilic membrane filters designed for reliable retention of spoilage microorganisms in the filtration of beer in the CFS NEO system or standard housings.
Description
The Pasteurizer Replacement filter cartridge family was developed and validated for removal of beer spoilage microorganisms in the CFS NEO system or standard housings.
The Pasteurizer Replacement filter cartridges are constructed from one layer of polyethersulfone (PES) membrane in a laid-over-pleat configuration. The single open ended (SOE) configuration is designed to fit into the sanitary housings on the CFS NEO system and standard housings to ensure effective microbial reduction and assembly integrity.
Pasteurizer Replacement filter cartridges are suitable for exposure to repeated hot water sanitization and in situ steam sterilization cycles for longer service life in the CFS NEO system. The optimized support and drainage materials, provide increased mechanical strength during operation, repeated hot water, chemical and steam sanitization and thus, high throughput.
Features | Benefits |
Cartridges resistant to numerous sanitization cycles |
|
Hydrophilic membranes |
|
Validated with beer spoilage microorganisms |
|
Individually serialized cartridges |
|
Integrity testable |
|
Quality
- Cartridges are produced in a controlled environment
- Manufactured according to ISO 9001:2015 certified Quality Management System
- All final filters are 100% integrity tested before manufacturing release
Food Contact Compliance
Please refer to the Pall website https://pall.com/en/food-beverage/compliance-and-safety.html for a Declaration of Compliance to specific National Legislation and/or Regional Regulatory requirements for food contact use.
Materials of Construction
Component | Description |
Filter Media* | Polyethersulfone (Hydrophilic) |
Support and Drainage | Polypropylene |
Core, Cage, End Cap and Fin End | Polypropylene |
Adaptor | Polypropylene with internal stainless steel reinforcing o-ring |
O-ring Seal | Ethylene propylene rubber or Silicone elastomer |
* Each 10” module contains 0.75m² (8.0 ft²) of effective filtration area.
CFS NEO System
Test Organism Log Reduction Value (LRV)
Final Membrane Filters |
Serratia marcescens (ATCC 14756) |
Lactobacillus brevis in beer |
Pediococcus damnosus in beer |
AB+PAREQII+W+ | 8 | 8 | 7 |
|
|
Technical Information
Operating Characteristics in Compatible Fluids1
Maximum Differential Pressure | Operating Temperature |
4.0 bard (58.0 psid) (forward pressure) | 80 °C (176 °F) |
1.0 bard (14.5 psid) (reverse pressure) | 40 °C (104 °F) |
1 Compatible fluids are defined as those which do not swell, soften or attack any of the filter componants.
Chemical Cleaning (static soak conditions)2
Media | Temperature | Cumulative Exposure |
Caustic 2% | 50 °C (122 °F) | 400 hours |
Caustic 2% | 80 °C (176 °F) | 200 hours |
2 Measured under laboratory test conditions. The actual cumulative time depends on the process conditions.
Pressure Drop3
Code | Value |
PAREQII | 42.5 l/min @ 100 mbar (7.6 US gal @1psi) |
3 Typical initial clean media differential pressure (dP) per 254 mm (10”) cartridge for water at 20°C (68°F), viscosity 1 centipoise. For 508, 762 and 1016 mm configurations, divide the differential pressure by 2, 3 and 4 respectively.
Sterilization and Sanitization
Media | Temperature | Cumulative Exposure |
Steam | 125 °C (257 °F) | 125 x 20 min cycles |
Hot water | 90 °C (194 °F) | 200 x 30 min cycles |
Peracetic acid (PAA), 325 ppm PPA (1275 ppm H2O2 to give 1600 ppm of total peroxides) |
Ambient | 2000 hours |
*Measured under laboratory test conditions. The actual cumulative time depends on the process conditions. For applications requiring sterilization or sanitization Pall recommends the use of Code 7 adaptors to ensure filter sealing after cooling. Cartridges should be cooled to system operating temperature prior to use. Contact Pall for recommended procedures.
Cartridge Part Number
AB [Table 1] PAREQII [Table 2] W [Table 3]
This is a guide to the Part Numbering structure only. For specific options, please contact Pall.
Table 1: Nominal Length
Code | Description |
1 | 254 mm (10”) |
2 | 508 mm (20”) |
3 | 762 mm (30”) |
4* | 1016 mm (40”) |
*40” filter elements are suitable for use in a CFS system
Table 2: Adaptor
Code | Description |
3 | SOE – single open end with flat closed end and external 222 O-rings |
7 | SOE – single open end with fin end, 2 locking tabs and external 226 O-rings |
8 | SOE – single open end with fin end and external 222 O-rings |
28 | SOE – single open end with fin end, 3 locking tabs and external 222 O-rings |
Table 3: O-Ring Seal Material
Code | Description |
H4 | Silicone Elastomer |
J | Silicone Elastomer J Ethylene Propylene Rubber |
Earn 10% off* your next order online by leaving a review of this product. Please login to your account to leave a review. We appreciate and value your feedback.